Example 2 - Mott-Schottky vs. Gouy-Chapman conditions

Running the code in this notebook takes approximately 32 minutes (example 1: under Gouy-Chapman takes approximately 21 minutes and example 2: under Mott-Schottky conditions takes approximately 11 minutes). (iMac with 4 Ghz i7 processor).

Space charge models typically consider dopant ions as either mobile or immobile. If the dopant ions are considered immobile, the model follows a Mott-Schottky approximation. If the dopant ions are considered mobile, the model follows a Gouy-Chapman approximation.

In [1]:
from pyscses.defect_species import DefectSpecies
from pyscses.set_of_sites import Set_of_Sites
from pyscses.constants import boltzmann_eV
from pyscses.calculation import Calculation, calculate_activation_energies
from pyscses.set_up_calculation import calculate_grid_offsets
from pyscses.grid import Grid

import numpy as np
import pandas as pd
import matplotlib.pyplot as plt
%matplotlib inline
In [2]:
boundary_conditions = 'dirichlet'
site_charges = False
systems = 'gouy-chapman'
core_models = False
site_models = 'continuum'
In [3]:
alpha = 0.0005

conv = 1e-8
grid_x_min = -2.0e-8
grid_x_max = +2.0e-8
bulk_x_min = -2.0e-8
bulk_x_max = -1.0e-8

dielectric = 1

index = 111

b = 5e-9
c = 5e-9

temp = [773.15]
In [4]:
valence = [ +1.0, -1.0 ]
site_labels = ['site_1', 'site_2']
defect_labels = ['defect_1', 'defect_2']
mole_fractions = [ [ 0.2, 0.2 ] ]
initial_guess = [ [ 0.2, 0.2 ] ]
mobilities = [ 1.0, 1.0 ]

Example 1 - Gouy-Chapman

systems = 'gouy-chapman'

The first approximation that can be applied is Gouy-Chapman conditions. This states that all defects in the system are mobile and able to redistribute over the system.

In [5]:
data = '../input_data/example_data_2_one_seg_energies.txt'
In [6]:
limits, laplacian_limits = calculate_grid_offsets( data, grid_x_min, grid_x_max, 'single' )

for m in mole_fractions:
    for t in temp:
    
        defect_species = { l : DefectSpecies( l, v, m, mob ) for l, v, m, mob in zip( defect_labels, valence, m, mobilities ) }

        all_sites = Set_of_Sites.set_of_sites_from_input_data( data, [grid_x_min, grid_x_max], defect_species, site_charges, core_models, t )
        if site_models == 'continuum':
            all_sites, limits = Set_of_Sites.form_continuum_sites( all_sites, grid_x_min, grid_x_max, 1000, b, c, defect_species, laplacian_limits, site_labels, defect_labels )
        if systems == 'mott-schottky':
            for site in all_sites.subset( 'site_2' ):
                site.defect_with_label('defect_2').fixed = True
        if systems == 'gouy-chapman':
            for site in all_sites.subset( 'site_2' ):
                site.defect_with_label('defect_2').fixed = False
        grid = Grid.grid_from_set_of_sites( all_sites, limits, laplacian_limits, b, c )
        
        c_o = Calculation( grid, bulk_x_min, bulk_x_max, alpha, conv, dielectric, t, boundary_conditions )
        c_o.form_subgrids( site_labels )
        if systems == 'gouy-chapman':
            c_o.mole_fraction_correction( m, systems, initial_guess )
        c_o.solve(systems)
        c_o.mole_fractions()
        c_o.calculate_resistivity_ratio( 'positive', 2e-2 )
--- 1301.7718060016632 seconds ---
In [7]:
plt.plot(grid.x, c_o.phi)
plt.xlabel( '$x$ $\mathrm{coordinate}$' )
plt.ylabel('$\Phi$ $\mathrm{( eV )}$')
plt.show()

plt.plot(grid.x, c_o.rho)
plt.xlabel( '$x$ $\mathrm{coordinate}$'  )
plt.ylabel(' $\mathrm{charge density}$ $(\mathrm{C m}^{-1})$')
plt.show()

plt.plot(grid.x, c_o.mf[site_labels[1]], label = '$\mathrm{defect_1}$')
plt.plot(grid.x, c_o.mf[site_labels[0]], label = '$\mathrm{defect_2}$')
plt.xlabel( '$x$ $\mathrm{coordinate}$'  )
plt.ylabel('$x_{i}$')
plt.legend()
plt.show()

Example 2 - Mott-Schottky

systems = 'mott-schottky'

The second approximation that can be applied is Mott-Schottky conditions. This states that one or more of the defects in the system are immobile and not able to redistibute over the system. For the calculation, these defect species are fixed to their bulk mole fractions.

for site in all_sites.subset( 'site_2' ):
        site.defect_with_label('defect_2').fixed = True
In [8]:
systems = 'mott-schottky'

limits, laplacian_limits = calculate_grid_offsets( data, grid_x_min, grid_x_max, 'single' )

for m in mole_fractions:
    for t in temp:
    
        defect_species = { l : DefectSpecies( l, v, m, mob ) for l, v, m, mob in zip( defect_labels, valence, m, mobilities ) }

        all_sites = Set_of_Sites.set_of_sites_from_input_data( data, [grid_x_min, grid_x_max], defect_species, site_charges, core_models, t )
        if site_models == 'continuum':
            all_sites, limits = Set_of_Sites.form_continuum_sites( all_sites, grid_x_min, grid_x_max, 1000, b, c, defect_species, laplacian_limits, site_labels, defect_labels )
        if systems == 'mott-schottky':
            for site in all_sites.subset( 'site_2' ):
                site.defect_with_label('defect_2').fixed = True
        if systems == 'gouy-chapman':
            for site in all_sites.subset( 'site_2' ):
                site.defect_with_label('defect_2').fixed = False
        grid = Grid.grid_from_set_of_sites( all_sites, limits, laplacian_limits, b, c )
        
        c_o = Calculation( grid, bulk_x_min, bulk_x_max, alpha, conv, dielectric, t, boundary_conditions )
        c_o.form_subgrids( site_labels )
        if systems == 'gouy-chapman':
            c_o.mole_fraction_correction( m, systems, initial_guess )
        c_o.solve(systems)
        c_o.mole_fractions()
        c_o.calculate_resistivity_ratio( 'positive', 2e-2 )
--- 671.9804339408875 seconds ---
In [9]:
plt.plot(grid.x, c_o.phi)
plt.xlabel( '$x$ $\mathrm{coordinate}$' )
plt.ylabel('$\Phi$ $\mathrm{( eV )}$')
plt.show()

plt.plot(grid.x, c_o.rho)
plt.xlabel( '$x$ $\mathrm{coordinate}$'  )
plt.ylabel(' $\mathrm{charge density}$ $(\mathrm{C m}^{-1})$')
plt.show()

plt.plot(grid.x, c_o.mf[site_labels[1]], label = '$\mathrm{defect_1}$')
plt.plot(grid.x, c_o.mf[site_labels[0]], label = '$\mathrm{defect_2}$')
plt.xlabel( '$x$ $\mathrm{coordinate}$'  )
plt.ylabel('$x_{i}$')
plt.legend()
plt.show()

It can be seen in the figures above that when fixed = True and the Poisson-Boltzmann equation is being calculated under Mott-schottky conditions defect_1 is able to redistribute whilst defect_2 is fixed to its bulk value. As the negatively charged defect_2 are fixed to its bulk positions they are not electrostatically attracted to the positively charged grain boundary core caused by the segregation of the positively charged defect_1. This causes a larger electrostatic potential at the grain boundary core as the segregation is not limited by the repulsion of the negatively charged defects adjacent to the core and also a broader potential profile as the negatively charged defects are not shielding the positive potential.